Back3.1.8.5.(2)

ATTRIBUTION:

Functional Statement:

F03

To retard the effects of fire on areas beyond its point of origin.

Objective:

OS1.2

 

APPLICATION:

Installation of doors, window assemblies or glass block used as closures in a required fire separation in buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of improper installation of closures, which could lead to the spread of fire from one fire compartment to another fire compartment, which could lead to harm to persons in the other fire compartment.

ATTRIBUTION:

Functional Statement:

F03

To retard the effects of fire on areas beyond its point of origin.

Objective:

OP1.2

 

APPLICATION:

Installation of doors, window assemblies or glass block used as closures in a required fire separation in buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of improper installation of closures, which could lead to the spread of fire from one fire compartment to another fire compartment, which could lead to damage to the building in the other fire compartment.