Back3.1.17.1.(4)

ATTRIBUTION:

Functional Statement:

F10

To facilitate the timely movement of persons to a safe place in an emergency.

Objective:

OS3.7

 

APPLICATION:

Calculation for design purposes of the occupant load for rooms or groups of rooms that are intended for different occupancies at different times, in buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of overcrowding, which could lead to delayed egress during emergency evacuation, which could lead to harm to persons.
To determine the minimum design occupant load in order to calculate egress and exit capacity, when rooms are intended for different occupancies at different times.

ATTRIBUTION:

Functional Statement:

F72

To provide facilities for the sanitary disposal of human and domestic wastes.

F71

To provide facilities for personal hygiene.

Objective:

OH2.1, OH2.3

 

APPLICATION:

Calculation for design purposes of the occupant load for rooms or groups of rooms that are intended for different occupancies at different times, in buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of overcrowding, which could lead to the inability of persons to use water closets and lavatories in a timely manner, which could lead to unsanitary conditions, which could lead to harm to persons.
To determine the minimum design occupant load in order to calculate the minimum number of water closets, when rooms are intended for different occupancies at different times.