Back3.2.3.16.(2)

ATTRIBUTION:

Functional Statement:

F03

To retard the effects of fire on areas beyond its point of origin.

Objective:

OS1.2

 

APPLICATION:

Protection of soffits, and any opening in the soffits or other surface of the projection located within 2 500 mm of a window or door opening, where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of the spread of fire from a suite or a patient's sleeping room through openings [e.g. windows or doors] in the exterior wall and then through openings in soffits, which could lead to the spread of fire through the common attic or roof space to other suites or patients' sleeping rooms, which could lead to harm to persons.

ATTRIBUTION:

Functional Statement:

F03

To retard the effects of fire on areas beyond its point of origin.

Objective:

OP1.2

 

APPLICATION:

Protection of soffits, and any opening in the soffits or other surface of the projection located within 2 500 mm of a window or door opening, where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.

INTENT:

To limit the probability of the spread of fire from a suite or a patient's sleeping room through openings [e.g. windows or doors] in the exterior wall and then through openings in soffits, which could lead to the spread of fire through the common attic or roof space, which could lead to damage to the building.