APPLICATION:
Vapour barriers installed to provide resistance to vapour diffusion through
building assemblies, and through interfaces between assemblies, that are subject to differentials
in temperature and water vapour pressure and where a lack of control of vapour
diffusion will not adversely affect health, safety, the intended use of the
building or the operation of
building services.
This also applies to the position of low air and vapour
permeance materials within the
building assembly relative to the position of materials providing thermal resistance in the
assemblies of
buildings to which Part 9 applies [see
Sentence
1.3.3.3.(1) of Division A for application of Part 9], where
the
building assembly:
- incorporates low permeance materials that act as other than
cladding or that are installed on the warm side of the assembly, and
- is more susceptible to condensation [see Sentences 9.25.1.2.(4) and (5) for combinations of interior and exterior environmental conditions that create
a higher risk for condensation].