Back9.8.9.5.(2)

ATTRIBUTION:

Functional Statement:

F22

To limit movement under expected loads and forces.

Objective:

OH4

 

APPLICATION:

Orientation of the face grain of stair treads made of plywood or OSB that are not continuously supported by the riser, for stairs within dwelling units, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
This also applies to stairs within dwelling units, in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3], as stated in Sentence 3.3.4.7.(1).

INTENT:

To limit the probability that stair treads spanning in the weak direction of the material will lead to excessive springiness or excessive deflection, which could lead to user anxiety.

ATTRIBUTION:

Functional Statement:

F20

To support and withstand expected loads and forces.

Objective:

OS2.1

 

APPLICATION:

Orientation of the face grain of stair treads made of plywood or OSB that are not continuously supported by the riser, for stairs within dwelling units, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
This also applies to stairs within dwelling units, in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3], as stated in Sentence 3.3.4.7.(1).

INTENT:

To limit the probability that stair treads spanning in the weak direction of the material will lead to structural failure, which could lead to harm to persons.