To control the accumulation and pressure of water
on and in the ground.
Objective:
OH1.1, OH1.2
APPLICATION:
Grading or drainage of heated and unheated crawl spaces
whose exterior walls have less than 25% of their total area above exterior
ground level open to the outdoors, in buildings to which Part 9 applies [see Sentence
1.3.3.3.(1) of Division A for application
of Part 9].
INTENT:
To limit the probability of:
the ingress of rainwater,
the ingress of surface water, or
for heated crawl spaces, the ingress of water, which could lead
to compromised thermal performance of components intended to provide resistance
to heat transfer.
This is to limit the probability of:
an inadequate control of the temperature of interior spaces
or relative humidity,
the generation of pollutants from biological growth or from
materials that become unstable on wetting, or
deterioration, which could lead to compromised integrity of
environmental separators or of elements protected by the separators.
This is to limit the probability of:
negative effects on the air quality of indoor spaces, and
the inadequate thermal comfort of persons.
This is to limit the probability of harm to persons.
ATTRIBUTION:
Functional Statement:
F60
To control the accumulation and pressure of water
on and in the ground.
Objective:
OS2.3
APPLICATION:
Grading or drainage of crawl spaces whose exterior
walls have less than 25% of their total area above exterior ground level open
to the outdoors, in buildings to which Part 9 applies [see Sentence
1.3.3.3.(1) of Division A for application of Part 9].
INTENT:
To limit the probability of:
the ingress of rainwater, or
the ingress of surface water.
This is to limit the probability of deterioration,
which could lead to compromised structural integrity of building components,
which could lead to harm to persons.