Back9.19.1.1.(1)

ATTRIBUTION:

Functional Statement:

F51

To maintain appropriate air and surface temperatures.

F62

To facilitate the dissipation of water and moisture from the building.

F51

To maintain appropriate air and surface temperatures.

Objective:

OH1.1, OH1.2, OH1.3

 

APPLICATION:

Venting of roof assemblies where insulation is installed above the ceiling and below the roof sheathing, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].

INTENT:

To limit the probability of inadequate venting, which could lead to:
  • condensation,
  • the accumulation of moisture, or
  • the formation of ice dams.
This is to limit the probability of:
  • the ingress of water, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to compromised integrity of ceilings acting as environmental separators, or
  • water accumulation in interior spaces.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.

ATTRIBUTION:

Functional Statement:

F62

To facilitate the dissipation of water and moisture from the building.

F51

To maintain appropriate air and surface temperatures.

Objective:

OS2.3

 

APPLICATION:

Venting of roof assemblies where insulation is installed above the ceiling and below the roof sheathing, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].

INTENT:

To limit the probability of inadequate venting, which could lead to:
  • condensation,
  • the accumulation of moisture, or
  • the formation of ice dams.
This is to limit the probability of deterioration, which could lead to compromised structural integrity of attic or roof assemblies or of elements protected by attic or roof assemblies, which could lead to harm to persons.