INTENT:
To limit the probability that the installation of spray-applied
polyurethane will fall significantly below expectations with regard to:
- spray equipment and operating parameters,
- chemicals or storage conditions,
- application procedures (including climatic conditions),
- physical properties (such as density, cohesion and adhesion),
and
- substrate type, condition and preparation.
This is to limit the probability of inadequate
thermal resistance, which could lead to excessively low temperatures of interior
surfaces or within assemblies.
This is to limit the probability of condensation, which could lead
to deterioration, which could lead to compromised structural integrity of
assemblies acting as environmental separators, which could lead to harm to
persons.