Back6.2.3.9.(2)

ATTRIBUTION:

Functional Statement:

F81

To minimize the risk of malfunction, interference, damage, tampering, lack of use or misuse.

F44

To limit the spread of hazardous substances beyond their point of release.

Objective:

OH1.1

 

APPLICATION:

Air duct systems, in heating, ventilating and air-conditioning systems, serving garages, in buildings described in Sentence 1.3.3.2.(1) of Division A.
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], with respect to:

INTENT:

To limit the probability that the interconnection of ductwork between the garage and other parts of the building will lead to the entry of gases, such as exhaust fumes from vehicles or other contaminants, into other parts of the building, which could lead to negative effects on the air quality of indoor spaces, which could lead to harm to persons.

ATTRIBUTION:

Functional Statement:

F81

To minimize the risk of malfunction, interference, damage, tampering, lack of use or misuse.

F44

To limit the spread of hazardous substances beyond their point of release.

Objective:

OS1.1

 

APPLICATION:

Air duct systems, in heating, ventilating and air-conditioning systems, serving garages, in buildings described in Sentence 1.3.3.2.(1) of Division A.
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], with respect to:

INTENT:

To limit the probability that the interconnection of ductwork between the garage and other parts of the building will lead to the spread of fire and products of combustion from the garage to other parts of the building, which could lead to harm to persons.

ATTRIBUTION:

Functional Statement:

F81

To minimize the risk of malfunction, interference, damage, tampering, lack of use or misuse.

F44

To limit the spread of hazardous substances beyond their point of release.

Objective:

OP1.1

 

APPLICATION:

Air duct systems, in heating, ventilating and air-conditioning systems, serving garages, in buildings described in Sentence 1.3.3.2.(1) of Division A.
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], with respect to:

INTENT:

To limit the probability that the interconnection of ductwork between the garage and other parts of the building will lead to the spread of fire from the garage to other parts of the building, which could lead to damage to the building.