Back9.8.4.1.(4)

ATTRIBUTION:

Functional Statement:

F30

To minimize the risk of injury to persons as a result of tripping, slipping, falling, contact, drowning or collision.

F10

To facilitate the timely movement of persons to a safe place in an emergency.

Objective:

OS3.1, OS3.7

 

APPLICATION:

Direction of turn for all sets of angled treads, including winders, in flights of interior and exterior stairs, for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
This also applies to stairs within dwelling units in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3], as stated in Sentence 3.3.4.7.(1).

INTENT:

To limit the probability that excessive variance in the configuration of a flight of stairs will excessively disrupt the gait of users or force them to switch to the other side of the stair, which could lead to:
  • persons misstepping and tripping, or
  • persons misstepping and tripping in an emergency, which could lead to delays in the evacuation or movement of persons to a safe place.
This is to limit the probability of harm to persons.