Back9.6.6.2.(2)

ATTRIBUTION:

Functional Statement:

F30

To minimize the risk of injury to persons as a result of tripping, slipping, falling, contact, drowning or collision.

F10

To facilitate the timely movement of persons to a safe place in an emergency.

F34

To resist or discourage unwanted access or entry.

Objective:

OS3.1, OS3.7, OS4.1

 

APPLICATION:

To all glass in sidelights and windows located within 915 mm of doors described in Article 9.6.8.1.

INTENT:

The intent of this sentence is to resist or discourage unwanted access or entry.