(See Appendix A.) (See Part 10)
[Rev. 2, B.C. Reg. 73/2008.]
1) Sound transmission class ratings shall be determined
in accordance with ASTM E 413, “Classification for Rating
Sound Insulation”, using the results from
measurements carried out in accordance with
a)ASTM E 90, “Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements”, or
b)ASTM E 336, “Measurement of Airborne Sound Insulation in Buildings”.
(See Appendix A.)1) Except as provided in Sentence (2), a dwelling unit shall be separated from every other space in a building in which noise may be generated by construction providing a sound
transmission class rating not less than 50, measured in
accordance with the standards referenced in Sentence 5.9.1.1.(1). (See A-9.11.1.1.(1) in Appendix A.)
2) Construction separating a dwelling unit from an elevator hoistway or a refuse chute shall
have a sound transmission class rating not less than 55,
measured in accordance with the standards referenced in Sentence 5.9.1.1.(1).