1) Sound transmission class ratings shall be determined
in accordance with ASTM E 413, “Classification for Rating Sound Insulation,”
using results from measurements in accordance with
a)ASTM E 90, “Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements,” or
b)ASTM E 336, “Measurement of Airborne Sound Insulation in Buildings.”
(See Appendix A.)1) Except as provided in Sentence (2), every dwelling unit shall be separated from every other space in a building in which noise may be generated by a construction providing a sound
transmission class rating of at least 50, measured in accordance
with Subsection 9.11.1. or as listed in A-9.10.3.1. in Appendix A.
2) Where a dwelling unit is adjacent to an elevator shaft or a refuse
chute, the separating construction shall have a sound
transmission class rating of at least 55, measured in accordance
with Subsection 9.11.1. or as listed in A-9.10.3.1. in Appendix A.