Division A
Compliance, Objectives and Functional Statements
Part 2 — Objectives
Section 2.2. Objectives
2.2.1. Objectives
2.2.1.1. Objectives
1) The objectives of this Code are as follows (see Appendix A):
OS Safety
An objective of this Code is to limit the probability that, as a
result of specific circumstances related to the building or facility, a person in or adjacent to the building or facility will be exposed to an unacceptable risk of injury.
OS1 Fire Safety
An objective of this Code is to limit the probability that, as a
result of
- activities related to the construction, use or demolition of the building or facility,
- the condition of specific elements of the building or facility,
- the design or construction of specific elements of the facility related to certain hazards, or
- inadequate built-in protection measures for the current or intended use of the building,
OS1.1 - fire or explosion occurring
OS1.2 - fire or explosion impacting areas beyond its point of
origin
OS1.3 - collapse of physical elements due to a fire or
explosion
OS1.4 - fire safety systems failing to function as
expected
OS1.5 - persons being delayed in or impeded from moving to a safe
place during a fire emergency
OS3 Safety in Use
An objective of this Code is to limit the probability that, as a
result of
- activities related to the construction, use or demolition of the building or facility,
- the condition of specific elements of the building or facility,
- the design or construction of specific elements of the facility related to certain hazards, or
- inadequate built-in protection measures for the current or intended use of the building,
OS3.1 - tripping, slipping, falling, contact, drowning or
collision
OS3.2 - contact with hot surfaces or substances
OS3.3 - contact with energized equipment
OS3.4 - exposure to hazardous substances
OS3.7 - persons being delayed in or impeded from moving to a safe
place during an emergency (see Appendix A)
OH Health
An objective of this Code is to limit the probability that, as a
result of specific circumstances related to the building or facility, a person will be exposed to an unacceptable risk of illness.
OH5 Hazardous Substances Containment
An objective of this Code is to limit the probability that, as a
result of
- activities related to the construction, use or demolition of the building or facility,
- the condition of specific elements of the building or facility,
- the design or construction of specific elements of the facility related to certain hazards, or
- inadequate built-in protection measures for the current or intended use of the building,
OP Fire Protection of Buildings and Facilities
An objective of this Code is to limit the probability that, as a
result of specific circumstances related to the building or facility, the building or facility will be exposed to an unacceptable risk of damage due to
fire.
OP1 Fire Protection of the Building or Facility
An objective of this Code is to limit the probability that, as a
result of
- activities related to the construction, use or demolition of the building or facility,
- the condition of specific elements of the building or facility,
- the design or construction of specific elements of the facility related to certain hazards, or
- inadequate built-in protection measures for the current or intended use of the building,
OP1.1 - fire or explosion occurring
OP1.2 - fire or explosion impacting areas beyond its point of
origin
OP1.3 - collapse of physical elements due to a fire or
explosion
OP1.4 - fire safety systems failing to function as
expected
OP3 Protection of Adjacent Buildings or Facilities from Fire
An objective of this Code is to limit the probability that, as a
result of
- activities related to the construction, use or demolition of the building or facility,
- the condition of specific elements of the building or facility,
- the design or construction of specific elements of the facility related to certain hazards, or
- inadequate built-in protection measures for the current or intended use of the building,
OP3.1 - fire or explosion impacting areas beyond the building or facility of origin