Division B
Acceptable Solutions

Part 10 — Energy and Water Efficiency

Section 10.3. Water Efficiency

10.3.1. Design and Installation

10.3.1.1. Fixture Fitting Maximum Flow Rates
1) The flow rates of fittings that supply water to plumbing fixtures must not exceed the maximum flow rate at the test pressures listed for that fitting in Table 10.3.1.1.
Table 10.3.1.1.
Maximum Flow Rate
Forming part of Sentence 10.3.1.1.(1)
Fittings Maximum Flow (L/min) Test Pressure (kPa)
Lavatory Faucet 8.3 415
Kitchen Faucet 8.3 415
Shower Head 9.5 550
10.3.1.2. Fixture Efficiency
1) change beginExcept as required by Sentence 10.3.1.2.(2),change end the flush cycle for the installation of a water closet or urinal must not exceed the flush cycle listed for that fixture in Table 10.3.1.2.(1)
Table 10.3.1.2.(1)
Maximum Flush Cycle
Forming part of Sentence 10.3.1.2.(1)
Fixture change beginLchange end
Water Closet (Tank Type) 6.0
Water Closet (Direct Flush) 6.0
Urinal (Tank Type) change begin1.9change end
Urinal (Direct Flush) change begin1.9change end
2) change beginThe flush cycle for the installation of a water closet or urinal in a Group C residential occupancy must not exceed the flush cycle listed for that fixture in Table 10.3.1.2.(2).change end
Table 10.3.1.2.(2)
change beginMaximum Flush Cycle
Forming part of Sentence 10.3.1.2.(1)
Fixture L
Water Closet (Tank Type) 4.8(1)
Water Closet (Direct Flush) 4.8
Urinal (Tank Type) 1.9
Urinal (Direct Flush) 1.9
Notes to Table 10.3.1.2.(2):

(1) A water closet with a dual flush cycle of 4.1 L or less and 6.0 L complies with this requirement.
3) The water supply to urinal flush tanks equipped for automatic flushing shall be controlled with a timing device in order to limit operation to the period during which the building is normally occupied.change end