Division B
Acceptable Solutions
Part 5 — Environmental Separation
Section 5.10. Standards
(See Appendix A and Part 10.)5.10.1. Applicable Standards
5.10.1.1. Compliance with Applicable Standards
1) Except as provided in
Sentence (2)
and elsewhere in this Part, materials and components, and their installation, shall conform to the
requirements of the applicable standards in Table 5.10.1.1. where those materials or components are


a) incorporated into environmental separators or assemblies exposed to the
exterior, and
b) installed to fulfill the requirements of this Part.
(See Appendix A.)2)
The requirements for flame-spread ratings contained in thermal insulation standards shall be applied only as required in Part 3.

Table 5.10.1.1. Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior Forming part of Sentence 5.10.1.1.(1) | ||
Issuing Agency | Document Number | Title of Document |
ANSI | A208.1 | Particleboard |
ASME | B18.6.1 | Wood Screws (Inch Series) |
ASTM | A 123/A 123M | Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products |
ASTM | A 153/A 153M | Zinc Coating (Hot-Dip) on Iron and Steel Hardware |
ASTM | A 653/A 653M | Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process |
ASTM | C 4 | Clay Drain Tile and Perforated Clay Drain Tile |
![]() ![]() | ![]() ![]() | ![]() ![]() |
ASTM | C 126 | Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units |
ASTM | C 212 | Structural Clay Facing Tile |
ASTM | C 412M | Concrete Drain Tile (Metric) |
ASTM | C 444M | Perforated Concrete Pipe (Metric) |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() |
C 700 | Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength,
and Perforated![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
ASTM | C 1002 | Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs |
ASTM | C 1177/C 1177M | Glass Mat Gypsum Substrate for Use as Sheathing |
ASTM | C 1178/C 1178M | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
![]() ![]() | ![]() ![]() | ![]() ![]() |
ASTM | C 1396/C 1396M | Gypsum Board |
ASTM | D 2178 | Asphalt Glass Felt Used in Roofing and Waterproofing |
![]() ![]() | ![]() ![]() | ![]() ![]() |
AWPA | M4 | Care of Preservative-Treated Wood Products |
![]() |
BNQ 3624-115 | Polyethylene (PE) Pipe and Fittings – Flexible Pipes for Drainage – Characteristics
and Test Methods ![]() |
CGSB | CAN/CGSB-11.3-M | Hardboard |
CGSB | CAN/CGSB-11.5-M | Hardboard, Precoated, Factory Finished, for Exterior Cladding |
CGSB | CAN/CGSB-12.1-M | Tempered or Laminated Safety Glass |
CGSB | CAN/CGSB-12.2-M | Flat, Clear Sheet Glass |
CGSB | CAN/CGSB-12.3-M | Flat, Clear Float Glass |
CGSB | CAN/CGSB-12.4-M | Heat Absorbing Glass |
CGSB | CAN/CGSB-12.8 | Insulating Glass Units |
CGSB | CAN/CGSB-12.10-M | Glass, Light and Heat Reflecting |
CGSB | CAN/CGSB-12.11-M | Wired Safety Glass |
CGSB | CAN/CGSB-34.22 | Asbestos-Cement Drain Pipe |
CGSB | CAN/CGSB-37.1-M | Chemical Emulsifier Type, Emulsified Asphalt for Dampproofing |
CGSB | CAN/CGSB-37.2-M | Emulsified Asphalt, Mineral-Colloid Type, Unfilled, for Dampproofing and Waterproofing and for Roof Coatings |
CGSB | CAN/CGSB-37.3-M | Application of Emulsified Asphalts for Dampproofing or Waterproofing |
CGSB | CAN/CGSB-37.4-M | Fibrated, Cutback Asphalt, Lap Cement for Asphalt Roofing |
CGSB | CAN/CGSB-37.5-M | Cutback Asphalt Plastic, Cement |
CGSB | 37-GP-6Ma | Asphalt, Cutback, Unfilled, for Dampproofing |
CGSB | CAN/CGSB-37.8-M | Asphalt, Cutback, Filled, for Roof Coating |
CGSB | 37-GP-9Ma | Primer, Asphalt, Unfilled, for Asphalt Roofing, Dampproofing and Waterproofing |
CGSB | 37-GP-12Ma | Application of Unfilled Cutback Asphalt for Dampproofing |
CGSB | CAN/CGSB-37.16-M | Filled, Cutback Asphalt for Dampproofing and Waterproofing |
CGSB | 37-GP-18Ma | Tar, Cutback, Unfilled, for Dampproofing |
CGSB | 37-GP-21M | Tar, Cutback, Fibrated, for Roof Coating |
CGSB | CAN/CGSB-37.22-M | Application of Unfilled, Cutback Tar Foundation Coating for Dampproofing |
CGSB | 37-GP-36M | Application of Filled Cutback Asphalts for Dampproofing and Waterproofing |
CGSB | 37-GP-37M | Application of Hot Asphalt for Dampproofing or Waterproofing |
CGSB | CAN/CGSB-37.50-M | Hot-Applied, Rubberized Asphalt for Roofing and Waterproofing |
CGSB | CAN/CGSB-37.51-M | Application for Hot-Applied Rubberized Asphalt for Roofing and Waterproofing |
CGSB | 37-GP-52M | Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric |
CGSB | CAN/CGSB-37.54 | Polyvinyl Chloride Roofing and Waterproofing Membrane |
CGSB | 37-GP-55M | Application of Sheet Applied Flexible Polyvinyl Chloride Roofing Membrane |
CGSB | 37-GP-56M | Membrane, Modified, Bituminous, Prefabricated, and Reinforced for Roofing |
CGSB | 37-GP-64M | Mat Reinforcing, Fibrous Glass, for Membrane Waterproofing Systems and Built-Up Roofing |
CGSB | 41-GP-6M | Sheets, Thermosetting Polyester Plastics, Glass Fiber Reinforced |
CGSB | CAN/CGSB-41.24 | Rigid Vinyl Siding, Soffits and Fascia |
CGSB | CAN/CGSB-51.32-M | Sheathing, Membrane, Breather Type |
CGSB | CAN/CGSB-51.33-M | Vapour Barrier Sheet, Excluding Polyethylene, for Use in Building Construction |
CGSB | CAN/CGSB-51.34-M | Vapour Barrier, Polyethylene Sheet for Use in Building Construction |
CGSB | CAN/CGSB-93.1-M | Sheet, Aluminum Alloy, Prefinished, Residential |
CGSB | CAN/CGSB-93.2-M | Prefinished Aluminum Siding, Soffits and Fascia, for Residential Use |
CGSB | CAN/CGSB-93.3-M | Prefinished Galvanized and Aluminum-Zinc Alloy Steel Sheet for Residential Use |
CGSB | CAN/CGSB-93.4 | Galvanized Steel and Aluminum-Zinc Alloy Coated Steel Siding, Soffits and Fascia, Prefinished, Residential |
CSA | A23.1 | Concrete Materials and Methods of Concrete Construction |
CSA | CAN/CSA-A82.1-M | Burned Clay Brick (Solid Masonry Units Made from Clay or Shale) |
CSA | A82.4-M | Structural Clay Load-Bearing Wall Tile |
CSA | A82.5-M | Structural Clay Non-Load-Bearing Tile |
CSA | CAN3-A82.8-M | Hollow Clay Brick |
CSA | CAN/CSA-A82.27-M | Gypsum Board |
CSA | A82.30-M | Interior Furring, Lathing and Gypsum Plastering |
CSA | A82.31-M | Gypsum Board Application |
CSA | CAN3-A93-M | Natural Airflow Ventilators for Buildings |
CSA | ![]() ![]() | Asphalt Shingles Made From Organic Felt and Surfaced with Mineral Granules![]() ![]() |
CSA | ![]() ![]() | Asphalt-Coated Roofing Sheets |
CSA | A123.3 | Asphalt Saturated Organic Roofing Felt |
CSA | CAN/CSA-A123.4 | Asphalt for Constructing Built-Up Roof Coverings and Waterproofing Systems |
CSA | A123.17 | Asphalt ![]() ![]() |
CSA | CAN3-A123.51-M | Asphalt Shingle Application on Roof Slopes 1:3 and Steeper |
CSA | CAN3-A123.52-M | Asphalt Shingle Application on Roof Slopes 1:6 to Less Than 1:3 |
CSA | ![]() ![]() | Concrete Block Masonry Units |
CSA | ![]() ![]() | Concrete Brick Masonry Units |
CSA | ![]() ![]() | Prefaced Concrete Masonry Units |
CSA | CAN3-A165.4-M | Autoclaved Cellular Units |
CSA | ![]() ![]() | Mortar and Grout for Unit Masonry |
![]() |
CAN/CSA-A220 Series | Concrete Roof Tiles![]() |
CSA | ![]() ![]() | Masonry Construction for Buildings |
CSA | CAN/CSA-A3001 | Cementitious Materials for Use in Concrete |
CSA | CAN/CSA-B182.1 | Plastic Drain and Sewer Pipe and Pipe Fittings |
CSA | CAN/CSA-G40.21 | ![]() ![]() |
CSA | ![]() ![]() | Corrugated Steel Pipe Products |
CSA | ![]() ![]() | Wood Preservation |
CSA | O115-M | Hardwood and Decorative Plywood |
CSA | O118.1 | Western Red Cedar Shakes and Shingles |
CSA | O118.2 | Eastern White Cedar Shingles |
CSA | O121 | Douglas Fir Plywood |
CSA | O141 | Softwood Lumber |
CSA | O151 | Canadian Softwood Plywood |
CSA | O153-M | Poplar Plywood |
CSA | CAN/CSA-O325 | Construction Sheathing |
CSA | O437.0 | OSB and Waferboard |
ULC | CAN/ULC-S701 | Thermal Insulation, Polystyrene, Boards and Pipe Covering |
ULC | CAN/ULC-S702 | Mineral Fibre Thermal Insulation for Buildings |
ULC | CAN/ULC-S703 | Cellulose Fibre Insulation (CFI) for Buildings |
ULC | CAN/ULC-S704 | Thermal Insulation, Polyurethane and Polyisocyanurate, Boards, Faced |
ULC | CAN/ULC-S705.1 | Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Material - Specification |
ULC | CAN/ULC-S705.2 | Thermal Insulation – Spray-Applied Rigid Polyurethane Foam, Medium Density ![]() ![]() |
![]() |
CAN/ULC-S706 | Standard for Wood Fibre Insulating Boards for Buildings![]() |
5.10.2.
Windows, Doors, Skylights and Other Glazed Products
5.10.2.1. General
1) This Subsection applies to windows, doors and skylights, other glazed
products and their components that separate
a) interior space from exterior space, or
b) environmentally dissimilar interior spaces.
2) For the purposes of this Subsection, the term “skylight” refers to unit
skylights, roof windows and tubular daylighting devices.
3) Windows, doors, skylights, other glazed products and their components that are required
to have a fire-protection rating need not conform to this Subsection. (See Appendix A.)
5.10.2.2. Design and Construction
1) Windows, doors, skylights and their components shall be designed and constructed in accordance with(See Appendix A.)
2) Other glazed products and their components shall be designed and
constructed in accordance with Subsection 5.1.4.,
Section 5.3., Section 5.4. and Section 5.6. (See Appendix A.)
3) For the purposes of conformance with Subclause (1)(b)(ii), loads and procedures from Section 5.2. may be used instead of the loads and procedures set out in the standard. (See Appendix A.)
5.10.2.3. [Reserved.]
5.10.2.4. Heat Transfer
1) 
Windows, doors and skylights shall meet the heat transfer performance requirements stated in Section 5.3. (See A-5.3.1.2. in Appendix A.)



2)
Except as provided in Sentence (3), all metal-framed glazed assemblies separating interior conditioned space from interior unconditioned space or exterior space shall incorporate a thermal break to minimize
condensation.

3)
Metal-framed glazed assemblies need not comply with Sentence (2) where these assemblies are

a) storm windows or doors, or
b) windows or doors that are required to have a fire-protection rating.
(See Appendix A.)