Division B
Acceptable Solutions

Part 2 — Plumbing Systems

Section 2.1. General

2.1.1. Application

2.1.1.1. Application
1) Intent StatementThis Part applies to all plumbing systems covered in this Code. (See Article 1.1.1.1. of Division A.)

2.1.2. Service Connections

2.1.2.1. Sanitary Drainage Systems
1) Intent Statementchange beginExcept as provided in Subsection 2.7.4.,change end every sanitary drainage system shall be connected to a public sanitary sewer, a public combined sewer or a private sewage disposal system.
2) Intent StatementA combined building drain shall not be installed. (See Appendix A.)
2.1.2.2. Storm Drainage Systems
1) Intent Statementchange beginExcept as provided in Subsection 2.7.4.,change end every storm drainage system shall be connected to a public storm sewer, a public combined sewer or a designated storm water disposal location.
2.1.2.3. Water Distribution Systems
1) Intent Statementchange beginExcept as provided in Subsection 2.7.4.,change end every water distribution system shall be connected to a public water main or a potable private water supply system.
2.1.2.4. Separate Services
1) Intent StatementPiping in any building connected to the public services shall be connected separately from piping of any other building, except that an ancillary building on the same property may be served by the same service. (See Appendix A.)

2.1.3. Location of Fixtures

2.1.3.1. Lighting and Ventilation Requirements
1) Plumbing fixtures shall not be installed in a room that is not lighted and ventilated in accordance with the appropriate requirements in Parts 3, 6 and 9 of Division B of change beginBook I (General) of this Codechange end.

contentHistory

2.1.3.2. Accessibility
1) Intent StatementEvery fixture, appliance, interceptor, cleanout, valve, device or piece of equipment shall be located so that it is readily accessible for use, cleaning and maintenance.